| • | If the control A circuit of the recirculation actuator is shorted to ground, the following conditions will occur. | 
| - | The recirculation actuator will operate properly when recirculation is requested. | 
| - | The recirculation actuator will continually modulate between the outside air and recirculation positions when outside air is requested. | 
| • | If the control B circuit of the recirculation actuator is shorted to ground, the following conditions will occur. | 
| - | The recirculation actuator will operate properly when outside air is requested. | 
| - | The recirculation actuator will continually modulate between the outside air and recirculation positions when recirculation is requested. | 
| • | The condition may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections . | 
| • | Inspect the recirculation door and the recirculation actuator for the following conditions: | 
| - | A misaligned recirculation actuator. | 
| - | Refer to Recirculation Actuator Replacement . | 
| - | Broken or binding linkages. | 
| - | A broken or binding recirculation door. | 
| - | An obstruction that prevents the recirculation door from operating within its full range of motion. | 
| - | Missing seals to the recirculation door. | 
| - | Misaligned seals to the recirculation door. | 
Step  | Action  | Yes  | No  | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics . Connector End View Reference: Component Connector End Views . DEFINITION: Air recirculation is inoperative or is always ON.  | |||||||||||||||||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |||||||||||||||
2  | 
 Do you hear an audible difference in the airflow when the recirculation switch is placed in the recirculation position?  | Go to Diagnostic Aids  | Go to Step 3  | ||||||||||||||
3  | 
 Does the drive shaft of the recirculation actuator rotate?  | Go to Diagnostic Aids  | Go to Step 4  | ||||||||||||||
4  | 
 Does the drive shaft of the recirculation actuator rotate?  | Go to Step 12  | Go to Step 5  | ||||||||||||||
5  | 
 Does the test lamp illuminate?  | Go to Step 6  | Go to Step 13  | ||||||||||||||
6  | 
 Does the test lamp illuminate with either command?  | Go to Step 7  | Go to Step 8  | ||||||||||||||
7  | 
 Does the test lamp illuminate with either command?  | Go to Step 10  | Go to Step 9  | ||||||||||||||
8  | Test the control A circuit of the recirculation actuator for an open, a high resistance, a short to ground or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 12  | ||||||||||||||
9  | Test the control B circuit of the recirculation actuator for an open, a high resistance, a short to ground or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 12  | ||||||||||||||
10  | Inspect the recirculation door and the recirculation actuator for the following conditions: 
 
 
 
 
 
 
 Did you find and correct the condition?  | Go to Step 16  | Go to Step 11  | ||||||||||||||
11  | Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 14  | ||||||||||||||
12  | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 15  | ||||||||||||||
13  | Repair the ignition 3 voltage circuit of the recirculation actuator. Refer to Wiring Repairs . Did you complete the repair?  | Go to Step 16  | --  | ||||||||||||||
14  | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement?  | Go to Step 16  | --  | ||||||||||||||
15  | Replace the HVAC control module. Refer to Control Module References . Did you complete the replacement?  | Go to Step 16  | --  | ||||||||||||||
16  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  | ||||||||||||||