Step  | Action  | Yes  | No  | ||||||
|---|---|---|---|---|---|---|---|---|---|
DEFINITION: Noise originating from the blower motor.  | |||||||||
1  | Were you sent here from Symptoms or another diagnostic table?  | Go to Step 2  | Go to Symptoms - HVAC Systems - Manual or to Symptoms - HVAC Systems - Automatic  | ||||||
2  | 
 Is the noise evident during blower operations?  | Go to Step 3  | Go to Step 10  | ||||||
3  | Does the noise vary with the blower speed?  | Go to Step 4  | Go to Step 10  | ||||||
4  | Inspect for excess vibration at each blower motor speed by feeling the blower case. Is excess vibration present?  | Go to Step 5  | Go to Step 10  | ||||||
5  | 
 Did you find any foreign material on the blower motor?  | Go to Step 7  | Go to Step 6  | ||||||
6  | Inspect the blower motor for the following conditions: 
 
 
 Did you find any of these conditions?  | Go to Step 8  | Go to Step 9  | ||||||
7  | Remove the foreign material. Is the action complete?  | Go to Step 10  | --  | ||||||
8  | Replace the blower motor. Refer to Blower Motor Replacement . Is the action complete?  | Go to Step 10  | --  | ||||||
9  | Install the blower motor. Refer to Blower Motor Replacement . Is the action complete?  | Go to Step 10  | --  | ||||||
10  | Operate the system in order to verify the repair. Did you find and correct the condition?  | System OK  | Go to Step 2  | ||||||