Tools Required
J 23600-B  Belt Tension
 Gauge
- Run the engine, with no accessories on, until the engine is warmed
up. Shut the engine off and read the belt tension using the J 23600-B 
 placed halfway between the generator
 and the power steering pump. Note the reading  and remove the J 23600-B 
.
 
- Start the engine with the accessories off and allow the system
to stabilize for 15 seconds. Turn the engine off. Using a 15 mm socket,
 apply clockwise force (tighten) to the tensioner pulley bolt. Release the
 force and immediately take a tension reading without disturbing belt tensioner
 position.
 
- Using the same wrench, apply a counterclockwise force to the tensioner
pulley bolt and raise the pulley to eliminate all tension. Slowly lower the
 pulley to the belt and take a tensioner reading without disturbing the belt
 tensioner position.
 
- Average the three readings. If the average of the three readings
is not between 133-222 N (30-50 lb) and the bolt
 is within the tensioners operating range, replace the tensioner.