Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the entire Exterior Lights System Check?  | --  | Go to Step 2  | |
2  | 
 Is battery voltage measured?  | B+  | Go to Step 3  | Go to Step 5  | 
3  | 
 Do the left turn lamps light?  | --  | Go to Step 4  | Go to Step 6  | 
4  | Replace the turn signal flasher. Is the repair complete?  | --  | --  | |
5  | Repair the open or the short to ground in CKT 539 (PNK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |
6  | Test CKT 16 (PPL) for an open or short to ground. Refer to Testing for Continuity or Testing for Short to Ground in Wiring Systems. Is CKT 16 OK?  | --  | Go to Step 7  | Go to Step 8  | 
7  | Replace the turn/hazard switch assembly. Is the repair complete?  | --  | --  | |
8  | Repair the suspect wiring. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  |