Step
| Action
| Value(s)
| Yes
| No
|
1
| Did you perform the Instrument Cluster System Check?
| --
| Go to
Step 2
| Go to
Instrument Cluster System Check
|
2
|
- Turn the ignition switch to OFF.
- Disconnect the instrument cluster connector C1.
- Turn the headlamp switch to PARK or HEAD.
- Turn the dimmer control to LO.
- Using a J 39200
digital multimeter (DMM), measure the voltage from the instrument cluster
connector C1 terminal F5 to ground.
Does the voltage equal the specified value?
| 12 V
| Go to
Step 4
| Go to
Step 3
|
3
| Inspect CKT 390 (YEL) for an open or short to ground.
Is the wiring OK?
| --
| Go to
Instrument Cluster System Check
| --
|
4
|
- Adjust the dimmer control.
- At the same time, measure the voltage from the instrument cluster
connector C1 terminal F4 (GRY) to ground.
Does the voltage vary with the dimmer control?
| --
| Go to
Step 6
| Go to
Step 5
|
5
|
- Connect the dimmer module connector.
- Adjust the dimmer control.
- At the same time, backprobe the dimmer module connector.
- Measure the voltage from terminal C to ground.
Does the voltage vary with the dimmer control?
| --
| Go to
Step 8
| Go to
Interior Lights Dimming System Check
|
6
| Inspect the instrument
cluster connector C1 terminal F4 and terminal F5 for
proper terminal contact.
Is the contact OK?
| --
| Go to
Step 7
| --
|
7
| Replace the instrument cluster.
Is the repair complete?
| --
| Go to
Instrument Cluster System Check
| --
|
8
| Inspect CKT 8 (GRY) for an open or short to ground.
Is the circuit OK?
| --
| Go to
Instrument Cluster System Check
| Go to
Step 9
|
9
| Repair the wiring.
Is the repair complete?
| --
| Go to
Instrument Cluster System Check
| --
|
Step
| Action
| Value(s)
| Yes
| No
|
1
| Did you perform the Instrument Cluster System Check?
| --
| Go to
Step 2
| Go to
Instrument Cluster System Check
|
2
|
- Turn the ignition switch to OFF.
- Disconnect the instrument cluster connector C2.
- Turn the headlamp switch to PARK or HEAD.
- Turn the dimmer control to LO.
- Using a J 39200
digital multimeter (DMM), measure the voltage from the instrument cluster
connector C1 terminal D11 to ground.
Does the voltage equal the specified value?
| 12 V
| Go to
Step 4
| Go to
Step 3
|
3
| Inspect CKT 390 (YEL) for an open or short to ground.
Is the wiring OK?
| --
| Go to
Instrument Cluster System Check
| --
|
4
|
- Adjust the dimmer control.
- At the same time, measure the voltage from the instrument cluster
connector C1 terminal C7 (BRN) to ground.
Does the voltage vary with the dimmer control?
| --
| Go to
Step 6
| Go to
Step 5
|
5
|
- Connect the dimmer module connector.
- Adjust the dimmer control.
- At the same time, backprobe the dimmer module connector.
- Measure the voltage from terminal C to ground.
Does the voltage vary with the dimmer control?
| --
| Go to
Step 8
| Go to
Interior Lights Dimming System Check
|
6
| Inspect the instrument
cluster connector C1 terminal C7 and terminal D11 for
proper terminal contact.
Is the contact OK?
| --
| Go to
Step 7
| --
|
7
| Replace the instrument cluster.
Is the repair complete?
| --
| Go to
Instrument Cluster System Check
| --
|
8
| Inspect CKT 1244 (BRN) for an open or short to ground.
Is the circuit OK?
| --
| Go to
Instrument Cluster System Check
| Go to
Step 9
|
9
| Repair the wiring.
Is the repair complete?
| --
| Go to
Instrument Cluster System Check
| --
|