Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Remote Keyless Entry System Check?  | --  | Go to Step 2  | |
2  | Is the remote keyless entry system inoperative from both transmitters?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Reprogram the transmitters. Refer to Transmitter Programming . Do the transmitters operate?  | --  | Go to Step 5  | |
4  | 
 Does the transmitter operate?  | Go to Step 10  | ||
5  | 
 Is the voltage within the specified range?  | 10-15 V  | Go to Step 7  | Go to Step 6  | 
6  | Repair the open or the short to ground in CKT 40 (ORN). Is the repair complete?  | --  | --  | |
7  | Measure the voltage between the RFA module connector terminals E16 and F16. Is the voltage within the specified range?  | 10-15 V  | Go to Step 9  | Go to Step 8  | 
8  | Repair the open in CKT 1050 (BLK). Is the repair complete?  | --  | --  | |
9  | Replace the RFA module. Refer to Remote Control Door Lock Receiver Replacement . Is the repair complete?  | --  | --  | |
10  | 
 Is the repair complete?  | --  | --  |