Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Horns System Check?  | --  | Go to Step 2  | Go to Horns System Check  | 
2  | Disconnect the horn relay. Are the horns on?  | --  | Go to Step 4  | Go to Step 3  | 
3  | Connect a test lamp between relay terminal 86 and terminal 85. Does the test lamp light?  | --  | Go to Step 6  | Go to Step 5  | 
4  | Repair a short to B+ in CKT 29 (DK GRN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Horns System Check  | --  | 
5  | Replace the horn relay. Refer to Horn Relay Replacement . Is the repair complete?  | --  | Go to Horns System Check  | --  | 
6  | 
 Are the horns on?  | --  | Go to Step 9  | Go to Step 8  | 
7  | Repair a short to ground in CKT 28 (BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Horns System Check  | --  | 
8  | Replace the horn switch. Is the repair complete?  | --  | Go to Horns System Check  | --  | 
9  | Disconnect the Remote Function Actuator (RFA) Module. Are the horns on?  | --  | Go to Step 7  | Go to Step 10  | 
10  | Replace the RFA Module. Refer to Remote Control Door Lock Receiver Replacement in Keyless Entry. Is the repair complete?  | --  | Go to Horns System Check  | --  |