Step
| Action
| Value(s)
| Yes
| No
|
1
| Did you perform the power windows
system check?
| --
| Go to Step
| Go to
Power Windows System Check
|
2
|
- Disconnect the LH front power window switch connector.
- Place the ignition switch in the RUN position.
- Place the window lockout switch in the LOCK position.
- Measure the voltage between the LH front power window switch connector
terminal S and ground.
Does the voltage measure within the specified range?
| 10-15 V
| Go to
Step
| Go to Step
|
3
|
- Disconnect the RH rear power window switch connector.
- Turn the ignition switch to the RUN position.
- Measure the voltage between the RH rear window switch connector
terminal F and ground.
Does the voltage measure within the specified range?
| 10-15 V
| Go to
Step
| Go to Step
|
4
| Replace the LH front power window switch. Refer to
Front Side Door Window Switch Replacement
.
Did you complete the repair?
| --
| Go to
Power Windows System Check
| --
|
5
| Repair a short to power in CKT 1307 (DK BLU). Refer to
Wiring Repairs
in Wiring Systems.
Did you complete the repair?
| --
| Go to
Power Windows System Check
| --
|