Removal Procedure
- Remove the HVAC Module. Refer to 
HVAC Module Assembly Replacement 
.
 
- Remove the mode actuator. Refer to
Mode Actuator Replacement 
in HVAC Systems - Automatic.
 
- Remove the left temperature actuator. 
 
- Remove the left temperature actuator screws. 
 
- Remove the fasteners that retain the mode actuator bracket.
 
- Remove the mode actuator bracket.
 
- Remove the upper module case screws in order to access
the  door.
 
- Open the module.
 
- Remove the actuator cam
 from the door.
 
- Remove the defroster door.
 
Installation Procedure
- Install the defroster door.
 
- Install the actuator cam
 to the door.
 
- Close the module case.
 
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the module  case screws.
 
Tighten
Tighten the screws to  1.4 N·m (12 lb in).
- Install the mode actuator and bracket. Refer to 
Mode Actuator Replacement 
in HVAC Systems - Automatic.
 
- Install the HVAC module. Refer to 
HVAC Module Assembly Replacement 
.