Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | Did you perform the Function Test?  | --  | Go to Step 2  | Go to Function Test  | ||||
2  | Inspect the affected valve actuator. Is the valve actuator correctly installed and connected?  | --  | Go to Step 3  | Go to Step 4  | ||||
3  | Disconnect the actuator from the valve. Inspect the valve. Does the valve display proper travel and effort?  | --  | Go to Step 5  | Go to Step 6  | ||||
4  | Repair the valve actuator. Is the repair complete?  | --  | Go to Function Test  | --  | ||||
5  | Inspect the vacuum connections for the following conditions: 
 
 Are the connections OK?  | --  | Go to Step 7  | Go to Step 8  | ||||
6  | Repair the valve. Is the repair complete?  | --  | Go to Function Test  | --  | ||||
7  | Inspect the actuator for proper operation. Repair the actuator. Is the repair complete?  | --  | Go to Function Test  | --  | ||||
8  | Repair the vacuum connector as necessary. Is the repair complete?  | --  | Go to Function Test  | --  |