Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Diagnostic System Check?  | --  | Go to Step 2  | Go to Diagnostic System Check  | 
2  | Verify that the blower motor is inoperative at any speed. Does the blower motor operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | Inspect the HVAC fuse in the underhood fuse block. Is the HVAC fuse open?  | --  | Go to Step 4  | Go to Step 7  | 
4  | 
 Important: The load side of the fuse is the terminal without battery voltage and the ignition switch in RUN. Is the reading less than the specified value?  | 0.5 ohms  | Go to Step 5  | Go to Step 6  | 
5  | Repair the short to ground in CKT 540. Is the repair complete?  | --  | Go to Step 22  | --  | 
6  | 
 Does the motor operate correctly?  | --  | Go to Step 22  | Go to Step 12  | 
7  | 
 Does the test lamp light?  | --  | Go to Step 8  | Go to Step 9  | 
8  | 
 Is the reading within the specified range?  | 2-4 V  | Go to Step 12  | Go to Step 15  | 
9  | Connect a test lamp between the blower motor connector terminal B and the battery ground. Does the test lamp light?  | --  | Go to Step 11  | Go to Step 10  | 
10  | Repair an open in CKT 540. Is the repair complete?  | --  | Go to Step 22  | --  | 
11  | Repair an open in CKT 850. Is the repair complete?  | --  | Go to Step 22  | --  | 
12  | 
 Caution: The jumpers must be of adequate gauge in order to handle the blower motor current. Does the blower motor operate at maximum speed?  | --  | Go to Step 14  | Go to Step 13  | 
13  | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the replacement complete?  | --  | Go to Step 22  | --  | 
14  | Replace the blower motor control module. Refer to Blower Motor Control Module Replacement . Is the replacement complete?  | --  | Go to Step 22  | --  | 
15  | Note the readings from the scan tool. Is the reading equivalent to the specified value?  | 0 V  | Go to Step 16  | Go to Step 22  | 
16  | 
 Does the test lamp light?  | --  | Go to Step 17  | Go to Step 18  | 
17  | Repair a short to ground in CKT 760. Is the repair complete?  | --  | Go to Step 22  | --  | 
18  | Connect a test lamp between the blower motor control module harness terminal A and terminal C. Does the test lamp light?  | --  | Go to Step 19  | Go to Step 20  | 
19  | Repair a short to battery in CKT 760. Is the repair complete?  | --  | Go to Step 22  | --  | 
20  | Replace the blower motor control module. Refer to Blower Motor Control Module Replacement Does the blower motor operate properly?  | --  | Go to Step 22  | Go to Step 21  | 
21  | Replace the ECC module. Refer to Control Assembly Replacement . Is the replacement complete?  | --  | Go to Step 22  | --  | 
22  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |