| Table 1: | Ambient Air Temperature Sensor | 
| Table 2: | Blower Motor Control Module | 
| Table 3: | Blower Motor Connector C1 | 
| Table 4: | Electric Actuator (Temperature) | 
| Table 5: | Electronic Climate Control (ECC) Module | 
| Table 6: | HVAC Vacuum Control Solenoid Valve | 
| Table 7: | Interior Air Temperature Sensor | 
| Table 8: | Inside Air Temperature Sensor (Distribution Duct) | 
| Table 9: | Inside Air Temperature Sensor (Floor Air Outlet) | 
| Table 10: | Sun Load Temperature Sensor | 
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
A  | BLK  | 552  | Sensor Return  | ||||
B  | DK GRN/WHT  | 636  | Ambient Air Temperature Sensor Signal  | ||||
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
A  | BLK  | 850  | Ground  | ||||
B  | ORN  | 540  | Fuse Output-Battey  | ||||
C  | PPL/WHT  | 760  | Blower Speed Signal-Speed Control-Low Energy  | ||||
D  | --  | --  | Not Used  | ||||
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
A  | PPL  | 65  | Blower Motor Feed  | ||||
B  | BLK  | 850  | Ground  | ||||
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
5  | BRN  | 341  | Fuse Output - Ignition  | ||||
6  | DK BLU  | 1199  | Air Temperature Valve Motor Feed  | ||||
7  | YEL  | 1791  | Air Temperature Valve Motor Return  | ||||
8  | --  | --  | Not Used  | ||||
9  | LT BLU  | 733  | Air Temperature Valve Position Sensor Signal  | ||||
10  | LT BLU/BLK  | 1688  | Reference Voltage Feed - 5 Volt Reference  | ||||
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
C1  | LT BLU/BLK  | 590  | Sun Load Temperature Sensor Input  | ||||
C2  | BRN  | 404  | Inside Air Temperature Sensor Signal (Distribution Duct)  | ||||
C3  | LT GRN  | 405  | Inside Air Temperature Signal (Floor Air Outlet)  | ||||
C4  | LT BLU  | 733  | Electric Actuator Feedback Signal  | ||||
C5  | --  | --  | Not Used  | ||||
C6  | BRN  | 341  | Fuse Output - Ignition 3  | ||||
C7  | GRY  | 1220  | Fuse Output - Instrument Panel Lamps  | ||||
C8  | --  | --  | Not Used  | ||||
C9  | DK BLU  | 1199  | Electric Actuator Feed  | ||||
C10  | BLK  | 1050  | Ground  | ||||
C11  | WHT  | 1038  | Serial Data Signal - Class 2  | ||||
C12  | ORN  | 340  | Fuse Output - Battery  | ||||
C13  | LT BLU  | 706  | Mode Valve Solenoid Output - Recirculation  | ||||
C14  | TAN  | 363  | Mode Valve Solenoid Output - Upper  | ||||
C15  | PPL  | 361  | Mode Valve Solenoid Output - Defrost  | ||||
C16  | PPL/WHT  | 760  | Blower Speed Signal - Speed Control - Low Energy  | ||||
D1  | DK GRN  | 734  | Interior Air Temperature Sensor Input  | ||||
D2  | DK GRN/WHT  | 636  | Ambient Air Temperature Sensor Input  | ||||
D3-D4  | --  | --  | Not Used  | ||||
D5  | LT BLU/BLK  | 1688  | 5 Volt Reference  | ||||
D6-D7  | --  | --  | Not Used  | ||||
D8  | LT BLU  | 203  | A/C Request for Air Conditioning Refrigerant High Pressure Cut-Out Switch Output  | ||||
D9  | BLK  | 552  | Sensor Ground  | ||||
D10  | YEL  | 1791  | Electric Actuator Sensor Return  | ||||
D11-D13  | --  | --  | Not Used  | ||||
D14  | WHT  | 193  | Rear Defogger Relay Output - Coil  | ||||
D15  | LT GRN/BLK  | 366  | Mode Valve Solenoid Output - Lower  | ||||
D16  | RED  | 362  | Mode Valve Solenoid Output - Panel Vents  | ||||
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
1  | PPL  | 361  | Mode Valve Solenoid Output - Defrost  | ||||
2  | RED  | 362  | Mode Valve Solenoid Output - Panel Vents  | ||||
3  | TAN  | 363  | Mode Valve Solenoid Output - Upper  | ||||
4  | LT GRN/BLK  | 366  | Mode Valve Solenoid Output - Lower  | ||||
5  | LT BLU  | 706  | Mode Valve Solenoid Output - Recirculation  | ||||
6  | BRN  | 341  | Fuse Output - Ignition 3  | ||||
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
A  | DK GRN  | 734  | Interior Air Temperature Sensor Signal  | ||||
B  | BRN  | 341  | Fuse Output Ignition  | ||||
C  | BLK  | 1850  | Ground  | ||||
D  | BLK  | 552  | Sensor Return  | ||||
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
A  | BRN  | 404  | Discharge Air Temperature Sensor Signal - Upper  | ||||
B  | BLK  | 552  | Sensor Return  | ||||
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
A  | LT GRN  | 405  | Inside Air Temperature Sensor Feed (Floor Air Outlet)  | ||||
B  | BLK  | 552  | Sensor Return  | ||||
 
 | |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information  | 
 
  | ||||||
Pin  | Wire Color  | Circuit No.  | Function  | ||||
A  | LT BLU/BLK  | 590  | Solar Sensor Signal - Drive  | ||||
B  | BLK  | 552  | Sensor Return  | ||||