Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Power Door Systems Diagnostic System Check?  | --  | Go to Step 2  | |
2  | Verify that the RF power window is inoperative. Do the power windows operate normally?  | --  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | 
3  | 
 Is ignition voltage present in both directions?  | B+  | Go to Step 4  | Go to Step 5  | 
4  | 
 Is ignition voltage present in both directions?  | B+  | Go to Step 10  | Go to Step 6  | 
5  | Test CKT's 166 (LT BLU), and 167 (TAN) for an open. Refer to Circuit Testing in wiring systems. Was an open present?  | --  | Go to Step 7  | Go to Step 8  | 
6  | Test CKT's 666 (DK BLU), and 667 (BRN) for an open. Refer to Circuit Testing in wiring systems. Was an open present?  | --  | Go to Step 7  | Go to Step 9  | 
7  | Repair the open in the appropriate circuit. Refer to Wiring Repairs in wiring systems. Is the repair complete?  | --  | Go to Step 11  | --  | 
8  | Replace the LH lock and side window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete?  | --  | Go to Step 11  | --  | 
9  | Replace the RH door lock and side window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete?  | --  | Go to Step 11  | --  | 
10  | Replace the right front side window regulator motor. Refer to Power Window Motor Replacement . Is the repair complete?  | --  | Go to Step 11  | --  | 
11  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |