Step  | Action  | Yes  | No  | ||||||
|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Exterior Lights Schematics  | |||||||||
1  | Did you perform the Lighting Systems Diagnostic System Check?  | Go to Step 2  | |||||||
2  | Verify that the stoplamps are always on. Do the stoplamps operate normally?  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | Go to Step 3  | ||||||
3  | Disconnect the stoplamp switch. Do the stoplamps remain illuminated?  | Go to Step 4  | Go to Step 7  | ||||||
4  | Disconnect the multifunction turn signal switch and the high mount stoplamp (CHMSL) relay (pickup only) and test for a short to voltage in the following circuits. Refer to Circuit Testing in Wiring Systems: 
 
 
 Was a problem found?  | Go to Step 6  | Go to Step 5  | ||||||
5  | 
 Did you complete the repair?  | Go to Step 8  | --  | ||||||
6  | Repair the short to voltage in one of the following circuits. Refer to Wiring Repairs in Wiring Systems: 
 
 
 Did you complete the repair?  | Go to Step 8  | --  | ||||||
7  | Replace the stoplamp switch. Refer to Stop Lamp Switch Replacement in Hydraulic Brakes. Did you complete the repair?  | Go to Step 8  | --  | ||||||
8  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  | ||||||