Slipping or Rough 1-2 Shift
Checks 
 | Causes 
 | 
Valve Body Assembly (60) 
 | 
|     •  | Mislocated valve body to spacer plate checkball or checkballs. |  
  
|     •  | 1-2 Shift valve train stuck due to sediment |  
  
|     •  | Gaskets or spacer plate incorrect, mispositioned or damaged |  
  
|     •  | 1-2 Accumulator valve stuck or damaged |  
  
|     •  | 4-3 sequence valve stuck or damaged |  
  
|     •  | #1 or #8 checkball missing or mis-located |  
  
|     •  | 1-2 accumulator valve bushing rotated 180° |  
  
 | 
2-4 Servo Assembly (13-28) 
 | 
|     •  | Apply pin too long or too short |  
  
|     •  | 2nd servo apply piston seal missing, cut or damaged |  
  
|     •  | Restricted or missing oil passages |  
  
|     •  | Servo bore in case damaged |  
  
 | 
2nd Accumulator (55-57, 104) 
 | 
|     •  | Porosity in 1-2 accumulator cover or piston |  
  
|     •  | Piston seal or groove damaged |  
  
|     •  | Nicks or burrs in 1-2 accumulator housing |  
  
|     •  | Missing or restricted oil passage |  
  
|     •  | 1-2 accumulator piston spring not seated |  
  
|     •  | Rough finish in 1-2 accumulator bore in case |  
  
|     •  | A cracked 1-2 accumulator piston - allowing fluid to leak by |  
  
 | 
2-4 Band (602) 
 | Worn or mispositioned 
 | 
Oil Pump Assembly (4) or Case (103) 
 | Faces not flat 
 |