Step  | Action  | Yes  | No  | 
|---|---|---|---|
DEFINITION: Noise originating from the blower motor.  | |||
1  | Were you sent here from the HVAC Symptoms?  | Go to Step 2  | Go to Symptoms - HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic  | 
2  | 
 Is a noise evident during the blower operation?  | Go to Step 3  | Go to Step 10  | 
3  | Inspect for excessive vibration at each blower motor speed by feeling the blower case. Is excess vibration present?  | Go to Step 5  | Go to Step 4  | 
4  | Listen to the blower motor at each speed. Is the blower motor making a squeaking or chirping noise?  | Go to Step 8  | Go to Step 10  | 
5  | Remove the blower motor. Refer to Blower Motor Replacement . Inspect the blower motor for deposits of foreign material. Did you find any foreign material on the blower motor?  | Go to Step 7  | Go to Step 6  | 
6  | Inspect the blower motor for the following conditions: 
 Did you find any of these conditions?  | Go to Step 8  | Go to Step 9  | 
7  | Remove the foreign material. Is the action complete?  | Go to Step 9  | --  | 
8  | Replace the blower motor. Refer to Blower Motor Replacement . Is the replacement complete?  | Go to Step 10  | --  | 
9  | Install the blower motor. Refer to Blower Motor Replacement . Is the action complete?  | Go to Step 10  | --  | 
10  | Operate the system in order to verify the repair. Does the system operate correctly?  | System OK  | Go to Step 2  |