Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Charging System Check ?  | --  | Go to Charging System Check  | |
2  | Check the battery hydrometer. Is the green dot visible in the hydrometer?  | --  | ||
3  | Diagnose the battery hydrometer. Refer to Battery Hydrometer Displays Dark or Yellow Dot . Is the charging system diagnosis complete?  | --  | --  | |
4  | Perform the battery load test. Refer to Battery Not Operating Properly . Did the battery pass the load test?  | --  | ||
5  | Replace the battery. Refer to Battery Replacement . Is the repair complete?  | --  | --  | |
6  | Check the generator. Refer to Generator Not Operating Properly . Does the generator operate properly?  | --  | ||
7  | 
 Is the measured voltage within the specified range?  | 4-14V  | ||
8  | Check CKT 225 (RED) and CKT 23 (GRY) for an intermittent short to ground or open condition. Are the circuits OK?  | --  | ||
9  | Repair CKT 225 (RED) or CKT 23 (GRY). Is the repair complete?  | --  | --  | |
10  | 
 Is the measured voltage within the specified range?  | 13-16V  | ||
11  | Check for an open or short to ground in CKT 225 (RED). Is the circuit OK?  | --  | ||
12  | Repair CKT 225 (RED). Is the repair complete?  | --  | --  | |
13  | 
 Is the repair complete?  | --  | --  | |
14  | Replace the generator. Refer to Generator Replacement . Is the repair complete?  | --  | --  | |
15  | 
 Is the system check complete?  | --  | System OK  | --  |