Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the Charging System Check ?  | --  | Go to Charging System Check  | |
2  | Check the battery hydrometer. Is the green dot visible in the hydrometer?  | --  | ||
3  | Diagnose the battery hydrometer. Refer to Battery Hydrometer Displays Dark or Yellow Dot . Is the charging system diagnosis complete?  | --  | --  | |
4  | Perform the battery load test. Refer to Battery Not Operating Properly . Did the battery pass the load test?  | --  | ||
5  | Replace the battery. Refer to Battery Replacement . Is the repair complete?  | --  | --  | |
6  | Check the generator. Refer to Generator Not Operating Properly . Does the generator operate properly?  | --  | ||
7  | 
 Is the charge indicator still on?  | --  | ||
8  | Service the instrument cluster. Refer to Battery Charge Indicator Inoperative in Instrument Panel, Gauges and Console. Is the repair complete?  | --  | --  | |
9  | 
 Is the repair complete?  | --  | --  | |
10  | Replace the generator. Refer to Generator Replacement . Is the repair complete?  | --  | --  | |
11  | 
 Is the system check complete?  | --  | System OK  | --  |