Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the entire Foglights System Check?  | --  | Go to Step 2  | Go to Fog Lights System Check  | 
2  | Disconnect the fog lamp switch connector. Do the fog lamps turn off?  | --  | Go to Step 6  | Go to Step 3  | 
3  | Disconnect the lamp control module connector C2. Do the fog lamps turn off?  | --  | Go to Step 7  | Go to Step 4  | 
4  | Remove the fog lamps relay from the RH IP fuse block. Do the fog lamps turn off?  | --  | Go to Step 8  | Go to Step 5  | 
5  | Repair the short to voltage in CKT 34 (PPL). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Fog Lights System Check  | --  | 
6  | Replace the fog lamp switch. Refer to Instrument Cluster Trim Panel Replacement in Instrument Panel, Gauges and Console. Is the repair complete?  | --  | Go to Fog Lights System Check  | --  | 
7  | Replace the lamp control module. Refer to Lamp Control Module Replacement . Is the repair complete?  | --  | Go to Fog Lights System Check  | --  | 
8  | Replace the fog lamps relay. Is the repair complete?  | --  | Go to Fog Lights System Check  | --  |