Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the entire Backup Lights System Check?  | --  | Go to Step 2  | Go to Backup Lamp System Check  | 
2  | Disconnect the park/neutral position switch connector C1. Do the backup lamps turn off?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Replace the park/neutral position switch. Refer to Park/Neutral Position Switch Replacement in Automatic Transaxle-4T65-E. Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  | 
4  | Is the vehicle equipped with lamp monitoring?  | --  | Go to Step 5  | Go to Step 7  | 
5  | Disconnect the lamp monitor control module connector C1. Do the backup lamps turn off?  | --  | Go to Step 6  | Go to Step 8  | 
6  | Inspect CKT 24 (LT GRN) for a short to voltage. Refer to Testing for Continuity in Wiring Systems. Is CKT 24 (LT GRN) OK?  | --  | Go to Step 9  | Go to Step 7  | 
7  | Repair the short to voltage in CKT 24 (LT GRN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  | 
8  | Inspect CKT 1524 (GRY) for a short to voltage. Refer to Testing for Continuity in Wiring Systems. Is CKT 1524 (GRY) OK?  | --  | Go to Step 10  | Go to Step 11  | 
9  | Replace the lamp monitor control module. Refer to Instrument Panel Lamp Dimmer Replacement in Instrument Panel, Gauges and Console. Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  | 
10  | Repair the short to voltage in CKT 24 (LT GRN) between C406 and S481. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  | 
11  | Repair the suspect wiring. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  | 
Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Did you perform the entire Backup Lights System Check?  | --  | Go to Step 2  | Go to Backup Lamp System Check  | 
2  | Disconnect the park/neutral position switch connector C1. Do the backup lamps turn off?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Replace the park/neutral position switch. Refer to Park/Neutral Position Switch Replacement in Automatic Transaxle-4T65-E. Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  | 
4  | Does the vehicle have cornering lamps?  | --  | Go to Step 6  | Go to Step 5  | 
5  | Remove the perimeter lighting relay from the RH IP fuse block. Do the backup lamps turn off?  | --  | Go to Step 7  | Go to Step 8  | 
6  | Disconnect the perimeter lighting relay connector. Do the backup lamps turn off?  | --  | Go to Step 7  | Go to Step 8  | 
7  | Replace the perimeter lighting relay. Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  | 
8  | Repair the short to voltage in CKT 24 (LT GRN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Backup Lamp System Check  | --  |