Headlights Circuit Description Buick
                    Battery positive voltage (B+) is supplied at all times
to the lamp control module (LCM) through the LH underhood fuse block LCM/HDLP
  circuit  breaker via CKT 242 (RED). When the headlamp switch is placed
  in the  ON position, the headlamp switch input to the LCM is grounded via
  CKT 103  (WHT). The LCM then supplies battery positive voltage (B+)
  via CKT 12  (TAN) to the following components:
|     •  | Right low beam headlamp | 
 
When the headlamp dimmer switch is placed in the HIGH position, the
LCM removes battery positive voltage (B+) from the low beam headlamps. The
   LCM supplies battery positive voltage (B+) via CKT 11 (LT GRN) to
  the  following components:
|     •  | Left high beam headlamp | 
 
|     •  | Right high beam headlamp | 
 
The LCM provides battery positive voltage (B+) to the appropriate headlamps
under the following conditions:
|     •  | The ignition switch is in the RUN position. | 
 
|     •  | The ambient light sensor indicates darkness. | 
 
The lamp control module (LCM) monitors the ambient light
conditions through the ambient light sensor. The ambient light sensor is a
   variable resistor whose resistance changes as the surrounding ambient light
   level changes. As the ambient light decreases, the resistance of the ambient
   light sensor increases. The LCM measures the resistance across the ambient
   light sensor and determines whether it is day or night.
                            Headlights Circuit Description Oldsmobile
                    Battery positive voltage (B+) is supplied through the LH
underhood fuse block LCM/HDLP circuit breaker via CKT 242 (RED) at
   all  times to the following components:
|     •  | Lamp control module (LCM) | 
 
|     •  | Switch of the RH IP fuse block headlamp relay position J | 
 
When the headlamp switch is placed in the ON position, battery positive
voltage (B+) is supplied via CKT 10 (YEL) to the coil of the headlamp
    relay position J. The coil  is permanently grounded to G201 via
 CKT 1450    (BLK). The coil is energized and the contacts close providing
 battery positive    voltage (B+) to the headlamp dimmer switch via CKT 1346
 (LT BLU).   When  the headlamp dimmer switch is in the LOW position,
 battery positive   voltage  (B+) is supplied via CKT 12 (TAN) to the
 following components:
|     •  | Right low beam headlamp | 
 
When the headlamp dimmer switch is in the HIGH position, battery positive
voltage (B+) is supplied via CKT 11 (LT GRN) to the following components:
|     •  | Left high beam headlamp | 
 
|     •  | Right high beam headlamp | 
 
The LCM provides battery positive voltage (B+) via CKT 1346 (LT
BLU) through the headlamp dimmer switch to the headlamps under the following
    conditions:
|     •  | The ignition switch is in the RUN position. | 
 
|     •  | The ambient light sensor indicates darkness. | 
 
The lamp control module (LCM) monitors the ambient light
conditions through the ambient light sensor. The ambient light sensor is a
     variable resistor whose resistance changes as the surrounding ambient
 light     level changes. As the ambient light decreases, the resistance of
 the ambient     light sensor increases. The LCM measures the resistance across
 the ambient     light sensor and determines whether it is day or night.
                            Headlights Circuit Description Pontiac
                    Battery positive voltage (B+) is supplied at all times
through the  LH underhood fuse block LCM/HDLP circuit breaker via CKT 242
   (RED) to the following components:
|     •  | Lamp control module (LCM) | 
 
When the headlamp switch is placed in the ON position, battery positive
voltage (B+) is supplied via CKT 10 (YEL) to the headlamp dimmer switch.
   When the headlamp dimmer switch is placed in the LOW position, battery
positive   voltage  (B+) is supplied via CKT 12 (TAN) to the  following
components:
|     •  | Right low beam headlamp | 
 
When the headlamp dimmer switch is in the HIGH position, battery positive
 voltage (B+) is supplied via CKT 11 (LT GRN) to the following components:
|     •  | Left high beam headlamp | 
 
|     •  | Right high beam headlamp | 
 
The LCM provides battery positive voltage (B+) via CKT 12 (TAN)
to the headlamps under the following conditions:
|     •  | The ignition switch is in the RUN position. | 
 
|     •  | The ambient light sensor indicates darkness. | 
 
When equipped with lamp monitoring, the headlamp battery positive voltage
(B+) feeds pass through the adaptive lamp monitor control module to the headlamps.
   The low beam headlamps receive battery positive voltage (B+) through CKT 1312
  (TAN or TAN/WHT). The high beam headlamps receive battery positive voltage
  (B+) through CKT 1311 (LT GRN, LT GRN/BLK or LT GRN/WHT)
The lamp control module (LCM) monitors the ambient light
conditions through the ambient light sensor. The ambient light sensor is a
   variable resistor whose resistance changes as the surrounding ambient light
   level changes. As the ambient light decreases, the resistance of the ambient
   light sensor increases. The LCM measures the resistance across the ambient
   light sensor and determines whether it is day or night.
                            Headlights Circuit Description Perimeter Lighting (Buick)
                    Perimeter lighting provides a personal security feature.
The perimeter lighting feature illuminates all exterior lights on the vehicle
    for 15 seconds when the  keyless entry transmitter is used to unlock
   the doors and it is dark outside.
The perimeter lighting system uses the following lamps:
When you press the UNLOCK button on the keyless entry transmitter, the
remote function actuator (RFA) module grounds CKT 624 (BLK/WHT) to
    the lamp control module (LCM). The LCM then provides battery positive
voltage      (B+) to the following components:
Battery positive voltage (B+) is supplied at all times through the IP
fuse block PERIMETER LT fuse 8A via CKT 1654 (TAN) to the  perimeter
   lighting relay. The RFA provides ground for the perimeter lighting  relay
  via   CKT 1655 (DK GRN). The coil is energized. The switch contacts
   close.   Battery positive voltage (B+) is provided to the following components:
|     •  | Cornering lamps (if equipped) | 
 
Refer to the following items for additional perimeter lighting schematics: