Step  | Action  | Value(s)  | Yes  | No  | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
1  | Did you perform the Power Door Locks System Check?  | --  | Go to Step 2  | |||||||
2  | 
 
 
 
 Does the MALL module sound 1 bong for each press of the switch?  | --  | Go to Step 3  | Go to Step 5  | ||||||
3  | 
 Is CKT 694 shorted to ground?  | --  | Go to Step 4  | Go to Step 10  | ||||||
4  | Repair CKT 694 (TAN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |||||||
5  | 
 Does the resistance measure within the specified range?  | 0-5 ohms  | Go to Step 6  | Go to Step 8  | ||||||
6  | Inspect the MALL module connector C2 for proper terminal contact at terminal C6. Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. Is the terminal contact OK?  | --  | Go to Step 10  | Go to Step 7  | ||||||
7  | Repair the terminal contact at the MALL module connector C2. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |||||||
8  | Test for an open in CKT 781 (ORN/BLK) between the MALL module connector C2 terminal C6 and S252. Is CKT 781 open?  | --  | Go to Step 9  | Go to Step 10  | ||||||
9  | Repair the open in CKT 781 (ORN/BLK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | --  | |||||||
10  | Replace the MALL module. Refer to Body Control Module Replacement in Body Control Systems. Is the repair complete?  | --  | --  |