The HVAC programmer receives battery voltage through circuit 40 from the I/P fuse block , fuse 9C.
| • | The ignition is ON. | 
| • | The circuit is open or shorted. | 
| • | Code 052 is set. | 
| • | The HVAC programmer will not operate. | 
| • | Using a Scan Tool . | 
| • | A history DTC will clear when 40 consecutive ignition cycles have occurred without a malfunction. | 
Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | Was the battery disconnected or recently discharged?  | --  | Go to Step 2  | Go to Step 3  | ||||
2  | Use Scan Tool to clear the DTC. Is the DTC clear?  | --  | System OK  | --  | ||||
3  | Use the Scan Tool in order to clear DTC 052. Does the DTC reset when cleared?  | --  | Go to Step 4  | System OK  | ||||
4  | Inspect the IP fuse block fuse 9C. Is the fuse OK?  | --  | Go to Step 7  | Go to Step 5  | ||||
5  | Check CKT 40 for a short to ground. Refer to Testing for Short to Ground in Wiring Systems. Did you find a short?  | --  | Go to Step 6  | Go to Step 7  | ||||
6  | Repair the short to ground in CKT 40. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | System OK  | --  | ||||
7  | 
 Refer to Measuring Voltage in Wiring Systems. 
 
 Refer to Measuring Voltage in Wiring Systems. Is battery voltage present?  | --  | Go to Step 8  | Go to Step 9  | ||||
8  | 
 Is the repair complete?  | --  | System OK  | --  | ||||