Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Check the HVAC fuse in the fuse block. Is the HVAC fuse open?  | --  | Go to Step 2  | Go to Step 3  | 
2  | Locate and repair a short to ground in circuit 41 (BRN). Is the repair complete?  | --  | System OK  | --  | 
3  | 
 Does the test lamp light?  | --  | Go to Step 5  | Go to Step 4  | 
4  | Locate and repair a poor connection or an open in circuit 41 (BRN). Is the repair complete?  | --  | System OK  | --  | 
5  | 
 Does the test lamp light?  | --  | Go to Step 8  | Go to Step 6  | 
6  | Check for poor connection or open in circuit 363 (TAN). Is there a poor connection or open in the circuit?  | --  | Go to Step 7  | Go to Step 10  | 
7  | Locate and repair the fault in circuit 363 (TAN). Is the repair complete?  | --  | System OK  | --  | 
8  | There is a fault in vacuum/electric solenoid, vacuum source, vacuum actuators, vacuum hoses to actuators, linkage from actuators to values, or faulty valves. Refer to Vacuum System for further diagnosis. Is the action complete?  | --  | System OK  | --  | 
9  | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete?  | --  | System OK  | --  |