Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Was the heater-A/C control diagnosis system check performed?  | --  | Go to Step 2  | Go to Diagnostic System Check  | 
2  | Check the HVAC fuse in the fuse block. Is the HVAC fuse open?  | --  | Go to Step 3  | Go to Step 4  | 
3  | Repair short to ground in circuit 41. Is the repair complete?  | --  | System OK  | --  | 
4  | 
 Is the measured voltage within the specified value?  | 9-14V  | Go to Step 6  | Go to Step 5  | 
5  | Repair poor connection or open in circuit 41. Is the repair complete?  | --  | System OK  | --  | 
6  | 
 Does the voltage vary?  | --  | Go to Step 7  | Go to Step 8  | 
7  | Replace the LH electric actuator. Refer to Temperature Actuator Replacement . Is the repair complete?  | --  | System OK  | --  | 
8  | Check for short to ground or short to B+ in circuit 1199. Is there a short to ground or short to B+ in circuit 1199?  | --  | Go to Step 9  | Go to Step 10  | 
9  | Repair short to ground or short to B+ in circuit 1199. Is the repair complete?  | --  | System OK  | --  | 
10  | Check for a poor connection or open in circuit 1199 between the heater-A/C control harness connector terminal C7 and the LH electric actuator harness connector terminal 6. Is there continuity in circuit 1199?  | --  | Go to Step 11  | Go to Step 12  | 
11  | Repair poor connection or open in circuit 1199 between the heater-A/C control harness connector terminal C7 and the LH electric actuator harness connector terminal 6. Is the repair complete?  | --  | System OK  | --  | 
12  | Replace the heater-A/C control. For manual systems refer to Control Assembly Replacement and for automatic systems refer to Control Assembly Replacement in Instrument Panel, Gauges and Console. Is the repair complete?  | --  | System OK  | --  |