Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Check the HVAC fuse in the fuse block. Is the HVAC fuse open?  | --  | Go to Step 2  | Go to Step 3  | 
2  | Locate and repair a short to ground in circuit 41 (BRN). Is the repair complete?  | --  | System OK  | --  | 
3  | 
 Does the test lamp light?  | --  | Go to Step 5  | Go to Step 4  | 
4  | Locate and repair a poor connection or an open in circuit 41 (BRN) between S 233 and the vacuum/electric solenoid. Is the repair complete?  | --  | System OK  | --  | 
5  | 
 Does the test lamp light?  | --  | Go to Step 8  | Go to Step 6  | 
6  | Check for poor connection or open in circuit 366 (LT GRN/BLK). Is there a poor connection or open in the circuit?  | --  | Go to Step 7  | Go to Step 11  | 
7  | Locate and repair the fault in circuit 366 (LT GRN/BLK). Is the repair complete?  | --  | System OK  | --  | 
8  | 
 Does the test lamp light?  | --  | Go to Step 9  | Go to Step 12  | 
9  | Use a DMM to test for a short to ground between the heater A/C control harness connector terminal D 10 and the vacuum/electric solenoid harness connector, terminal 2. Is there a short to ground?  | --  | Go to Step 10  | G to Step 11  | 
10  | Locate and repair the short to ground in circuit 362 (RED). Is the repair complete?  | --  | System OK  | --  | 
11  | Replace the heater-A/C control. For manual systems refer to Control Assembly Replacement and for automatic systems refer to Control Assembly Replacement in Instrumant Panel, Gauges and Console. Is the repair complete?  | --  | System OK  | --  | 
12  | Replace the vacuum/electric solenoid. Refer to Vacuum Electrical Solenoid Replacement in Instrument Panel, Guages and Console Is the repair complete?  | --  | System OK  | --  |