Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | 
 Is the resistance measured greater than specified?  | 0.15 ohms  | ||
2  | 
 Does the DMM indicate intermittent continuity?  | --  | ||
3  | Is the coax cable type RG-58 or RG-59?  | --  | ||
4  | Is the measured resistance less than 0.2ohms?  | --  | ||
5  | For RG-62 or RG-62M, does the measured resistance approximately equal the value?  | Less than 3.5ohms  | ||
6  | While observing the DMM, wiggle the antenna coax. Does the meter indicate intermittent continuity?  | --  | ||
7  | 
 Is the voltage measured within the specified value?  | 10-14V  | ||
8  | Check the radio antenna module and the coaxial cable interconnects for a poor connection or corrosion. Are all connections clean, tight and free of corrosion?  | --  | ||
9  | Using a DMM, measure the voltage between the radio antenna module harness connector terminal A and ground. Is the voltage measured within the specified range?  | 10-14V  | ||
10  | 
 Is the repair complete?  | --  | --  | |
11  | Replace the radio antenna module. Refer to Radio Speaker Amplifier Replacement for service procedure. Is the repair complete?  | --  | --  | |
12  | Repair poor connection or open in circuit 351. Is the repair complete?  | --  | --  | |
13  | Repair poor connection or open in circuit 145. Is the repair complete?  | --  | --  |