Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Was the power sunroof system check performed?  | --  | Go to Step 2  | |
2  | 
 Does the LF power window operate?  | --  | Go to Step 8  | Go to Step 6  | 
3  | 
 Is the voltage measured within the specified range?  | 4.5-5.5V  | Go to Step 4  | Go to Step 19  | 
4  | Using a DMM, measure the voltage by backprobing between the sunroof switch harness connector terminal C and ground. Is the voltage measured within the specified range? (Note: if the DMM displays B+, then go to step 39).  | 4.5-5.5V  | Go to Step 5  | Go to Step 23  | 
5  | Using a DMM, measure the voltage by backprobing between the sunroof switch harness connector terminals B and F. Is the voltage measured within the specified range?  | 4.5-5.5V  | Go to Step 10  | Go to Step 26  | 
6  | Check the PWR WINDOWS PWR SUNROOF circuit breaker located in the fuse block. Is the PWR WINDOWS PWR SUNROOF circuit breaker open?  | --  | Go to Step 7  | Go to Step 8  | 
7  | Repair short to ground in circuit 143. Is the repair complete?  | --  | --  | |
8  | Using a test light, connect by backprobing between C398 terminal A and ground. Is the test light on?  | --  | Go to Step 9  | Go to Step 28  | 
9  | 
 Is the test light on?  | --  | Go to Step 3  | Go to Step 29  | 
10  | 
 Is the test light on?  | --  | Go to Step 11  | Go to Step 22  | 
11  | 
 Is the test light on?  | --  | Go to Step 14  | Go to Step 22  | 
12  | 
 Is the test light on?  | --  | Go to Step 13  | Go to Step 30  | 
13  | 
 Is the test light on?  | --  | Go to Step 18  | Go to Step 30  | 
14  | 
 Is the voltage measured within the specified range? (Note: if voltage measured is B+, then go to step 39).  | 4.5-5.5V  | Go to Step 15  | Go to Step 31  | 
15  | Using a DMM, measure the voltage by backprobing between the limit switch module harness connector C4 terminal 3 and ground. Is the voltage measured within the specified range? (Note: if voltage measured is B+, then go to step 39).  | 4.5-5.5V  | Go to Step 16  | Go to Step 34  | 
16  | Using a DMM, measure the voltage by backprobing between the limit switch module harness connector C4 terminal 4 and ground. Is the voltage measured within the specified range? (Note: if voltage measured is B+, then go to step 39).  | 4.5-5.5V  | Go to Step 17  | Go to Step 36  | 
17  | Using a DMM, measure the voltage by backprobing between the limit switch module harness connector C4 terminals 2 and 4. Is the voltage measured within the specified range?  | 4.5-5.5V  | Go to Step 12  | Go to Step 38  | 
18  | Replace the sunroof actuator. Refer to Power Sunroof Motor Replacement Power Sunroof Motor Replacement for service procedure. Is the repair complete?  | --  | --  | |
19  | 
 Is the voltage measured within the specified range?  | 4.5-5.5V  | Go to Step 21  | Go to Step 20  | 
20  | Locate open or short to ground in circuit 100. Is there an open or short to ground in circuit 100?  | --  | Go to Step 40  | Go to Step 22  | 
21  | Replace the sunroof switch. Refer to Sunroof Switch Replacement Power Sunroof Switch Replacement for service procedure. Is the repair complete?  | --  | --  | |
22  | Replace the sunroof module. Refer to Power Sunroof Express Module Replacement Power Sunroof Express Module Replacement for service procedure. Is the repair complete?  | --  | --  | |
23  | 
 Is the measured voltage within the specified value?  | 4.5-5.5V  | Go to Step 21  | Go to Step 24  | 
24  | Repair open or short to ground in circuit 110. Is the repair complete?  | --  | --  | |
25  | Repair the open or short to ground. Is the repair complete?  | --  | --  | |
26  | 
 Is the measured resistance within the specified range?  | Less than 2ohms  | Go to Step 22  | Go to Step 27  | 
27  | Repair poor connection or open in circuit 128. Is the repair complete?  | --  | --  | |
28  | Repair poor connection or open in circuit 143. Is the repair complete?  | --  | --  | |
29  | Repair poor connection or open in circuit 850. Is the repair complete?  | --  | --  | |
30  | Repair poor connection or open in circuit 127 or circuit 129. Is the repair complete?  | --  | --  | |
31  | 
 Is the voltage measured within the specified range?  | 4.5-5.5V  | Go to Step 33  | Go to Step 32  | 
32  | Locate open or short to ground in the BLK wire between the sunroof module harness connector C1 terminal 6 and the limit switch module harness connector C4 terminal 1. Is there an open or short to ground in the BLK wire?  | --  | Go to Step 41  | Go to Step 22  | 
33  | Replace the limit switch module. Is the repair complete?  | --  | --  | |
34  | 
 Is the voltage measured within the specified range?  | 4.5-5.5V  | Go to Step 33  | Go to Step 35  | 
35  | Locate open or short to ground in WHT wire between the sunroof module harness connector C1 terminal 8 and the limit switch module harness connector C4 terminal 3. Is there an open or short to ground in the WHT wire?  | --  | Go to Step 42  | Go to Step 22  | 
36  | 
 Is the voltage measured within the specified range?  | 5.5-6.5V  | Go to Step 33  | Go to Step 37  | 
37  | Locate open or short to ground in the RED wire between the sunroof module harness connector C1 terminal 7 and the limit switch module harness connector C4 terminal 4. Is there an open or short to ground in the RED wire?  | --  | Go to Step 43  | Go to Step 22  | 
38  | Locate open in the BLK/WHT wire between the sunroof module harness connector C1 terminal 1 and the limit switch module harness connector C4 terminal 2. Is there an open in the BLK/WHT wire?  | --  | Go to Step 44  | Go to Step 22  | 
39  | Repair the short to B+. Is the repair complete?  | --  | --  | |
40  | Repair the open or short to ground in circuit 100. Is the repair complete?  | --  | --  | |
41  | Repair open or short to ground in the BLK wire between the sunroof module harness connector C1 terminal 6 and the limit switch module harness connector C4 terminal 1. Is the repair complete?  | --  | --  | |
42  | Repair open or short to ground in the WHT wire between the sunroof module harness connector C1 terminal 8 and the limit switch module harness connector C4 terminal 3. Is the repair complete?  | --  | --  | |
43  | Repair open or short to ground in the RED wire between the sunroof module harness connector C1 terminal 7 and the limit switch module harness connector C4 terminal 4. Is the repair complete?  | --  | --  | |
44  | Repair open in the BLK/WHT wire between the sunroof module harness connector C1 terminal 1 and the limit switch module harness connector C4 terminal 2. Is the repair complete?  | --  | --  |