Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Is the LOW WASHER FLUID level indicator on with the wash fluid level is OK?  | --  | Go to Step 3  | Go to Step 2  | 
2  | Is the LOW WASHER FLUID level indicator off with the washer fluid level low?  | --  | Go to Step 8  | System OK  | 
3  | 
 Is the LOW WASHER FLUID level indicator on?  | --  | Go to Step 5  | Go to Step 4  | 
4  | Replace the windshield washer solvent level switch. Refer to Windshield Washer Solvent Container Replacement for service procedure. Is the repair complete?  | --  | Go to Step 15  | --  | 
5  | 
 Is the measured resistance same as the specified value?  | ∞  | Go to Step 7  | Go to Step 6  | 
6  | Repair short to ground in circuit 99. Is the repair complete?  | --  | Go to Step 15  | --  | 
7  | Replace the instrument cluster. Refer to Instrument Cluster Replacement for service procedure. Is the repair complete?  | --  | Go to Step 15  | --  | 
8  | 
 Is the LOW WASHER FLUID level indicator on?  | --  | Go to Step 9  | Go to Step 12  | 
9  | 
 Is the LOW WASHER FLUID level indicator on?  | --  | Go to Step 10  | Go to Step 11  | 
10  | Replace the windshield washer solvent level switch. Refer to Windshield Washer Solvent Container Replacement for service procedure. Is the repair complete?  | --  | Go to Step 15  | --  | 
11  | Repair poor connection or open in circuit 1250 between the windshield washer solvent level switch terminal B and G102. Is the repair complete?  | --  | Go to Step 15  | --  | 
12  | 
 Is the measured resistance within the specified value?  | Less than 3ohms  | Go to Step 13  | Go to Step 14  | 
13  | Replace the instrument cluster. Refer to Instrument Cluster Replacement for service procedure. Is the repair complete?  | --  | Go to Step 15  | --  | 
14  | Repair poor connection or open in circuit 99. Is the repair complete?  | --  | Go to Step 15  | --  | 
15  | 
 Are there any instrument cluster DTCs present?  | --  | System OK  |