- Using a small screwdriver, pry the wiring
harness (224/225) electrical connectors  off of the following components:
 
| •  | Automatic transaxle fluid pressure manual valve position switch
 assembly (395) | 
 
| •  | 1-2, 3-4 Shift solenoid valve assembly (315A) | 
 
| •  | 2-3 Shift solenoid valve assembly (315B) | 
 
| •  | TCC PWM solenoid valve assembly (334) | 
 
| •  | Pressure control solenoid valve assembly (322) | 
 
| •  | Automatic transaxle input speed sensor assembly (440) | 
 
- Gently pull the automatic transaxle fluid temperature sensor (391)
 from it's clip.
 
- Lift the wiring harness assembly (224/225)
off of the transaxle.