The HVAC programmer commands the actuator to move by suppling battery voltage. The feedback supplied to the HVAC programmer is a regulated 5 volts. The feedback voltage is a function of the motor position with a high voltage of 4-5 volts indicating full cold door position. A low voltage of less than 1 volt indicates the full hot position. Operation of the air mix door actuator can be evaluated through the Scan Tool .
The ignition is ON.
Only the full hot or full cold may be used by the system.
| • | Using a Scan Tool . | 
| • | A history DTC will clear when 40 consecutive IGN cycles have occurred without a malfunction. | 
| • | HVAC programmer battery voltage is interrupted. | 
Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | 
 Refer to Measuring Voltage in Wiring Systems. Does the voltage equal the specified value?  | 5 V  | Go to Step 2  | Go to Step 3  | ||||
2  | Measure the voltage between passenger air mix valve actuator connector (harness side) terminal 8 and terminal 9. Refer to Measuring Voltage in Wiring Systems. Is the voltage greater than or equal to the specified value?  | 4 V  | Go to Step 4  | Go to Step 3  | ||||
3  | 
 Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. 
 
 Is the repair complete?  | --  | System OK  | --  | ||||
4  | 
 
 
 Refer to Intermittents and Poor Connections Diagnosis in Wiring Systems. Is the repair complete?  | --  | System OK  | --  |