Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | Inspect the T/SIG fuse. Is the fuse open?  | --  | Go to Step 2  | Go to Step 3  | ||||
2  | Repair a short to ground in one of the following circuits: 
 
 Is the repair complete?  | --  | --  | |||||
3  | 
 Did the test lamp light?  | --  | Go to Step 5  | Go to Step 4  | ||||
4  | Repair the following conditions in CKT 539: 
 
 Is the repair complete?  | --  | --  | |||||
5  | Use a test light in order to backprobe between connector C201 terminal E1 and ground. Does the test light illuminate?  | --  | Go to Step 7  | Go to Step 6  | ||||
6  | 
 Is the repair complete?  | --  | --  | |||||
7  | Use a test light to backprobe the hazard lamp/turn signal flasher between connector terminal A1 and connector terminal B2. Does the test light illuminate?  | --  | Go to Step 9  | Go to Step 8  | ||||
8  | Repair the following conditions, as needed: 
 
 Has the repair been made?  | --  | --  | |||||
9  | 
 Is the test light flashing?  | --  | Go to Step 11  | Go to Step 10  | ||||
10  | Replace the turn signal/hazard lamp flasher. Refer to Hazard and Turn Signal Flasher Replacement . Has the repair been made?  | --  | --  | |||||
11  | 
 Is the test light flashing?  | --  | Go to Step 6  | Go to Step 12  | ||||
12  | Repair the faulty connection or the open in CKT 16. Has the repair been made?  | --  | --  |