Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Inspect the FRT PWR SCKT fuse. Is the FRT PWR SCKT fuse open?  | --  | Go to Step 2  | Go to Step 3  | 
2  | Repair short to ground in circuit 1940. Has the repair been made and the system rechecked?  | --  | System OK  | --  | 
3  | Use a test light in order to backprobe between the front electric accessory plug housing terminal A and ground. Does the test lamp light?  | --  | Go to Step 5  | Go to Step 4  | 
4  | Repair the open in circuit 1940. Has the repair been made and the system rechecked?  | --  | System OK  | --  | 
5  | Use a test light in order to backprobe between the front electric accessory plug housing terminal A and terminal B. Does the test lamp light?  | --  | Go to Step 7  | Go to Step 6  | 
6  | Repair a poor connection or open in circuit 150. Has the repair been made and the system rechecked?  | --  | System OK  | --  | 