Step 
 | Action 
 | Value(s) 
 | Yes 
 | No 
 | 
1 
 | Do the exterior turn lamps flash? 
 | -- 
 | Go to 
Step 2
         
 | Go to 
Exterior Lights System Check 
in Lighting Systems 
 | 
2 
 | Does the high beam
indicator work with the high beams on? 
 | -- 
 | Go to 
Step 3
        
 | Go to 
Instrument Cluster Illumination Lamps Inoperative  
 | 
3 
 | Check for a poor connection or
open in the following circuits: 
|     •  | (Left) CKT 18 between the instrument cluster harness connector C2
terminal P and S233. |  
  
|     •  | (Right) CKT 19 between the instrument cluster harness connector C2
terminal R and S232. |  
  
Is there a poor connection or open. 
 | -- 
 | Go to 
Step 4
        
 | Go to 
Step 5
        
 | 
4 
 | Repair the poor connection or open in the following circuits: 
|     •  | (Left) CKT 18 between the instrument cluster harness connector C2
terminal P and S233. |  
  
|     •  | (Right) CKT 19 between the instrument cluster harness connector C2
terminal R and S232. |  
  
Has the repair been made and the system rechecked? 
 | -- 
 | System OK 
 | -- 
 | 
5 
 | 
- Check the warning indicator bulb and bulb connection.
 
- If OK, replace the instrument cluster. Refer to 
Instrument Cluster Replacement 
.
 
 
Has the repair been made and the system rechecked? 
 | -- 
 | System OK 
 | -- 
 |