Removal Procedure
- Disconnect the MAF sensor electrical connector.
 
- Loosen the air intake duct/MAF sensor hose clamps.
 
- Remove the air intake duct/MAF sensor assembly (1).
 
- Unsnap the 2 housing cover
retaining clamps.
 
- Remove the air cleaner cover (2) and carefully remove the
air filter element (3).
 
- Inspect the housing cover, seal assembly, and air ducting for
damage. If a problem is found, replace as necessary.
 
Installation Procedure
- Carefully install the
air filter element (3) into the air cleaner assembly.
 
- Install the housing cover (2) and snap the retaining clamps
in place.
 
- Install the air intake duct/MAF sensor assembly (1).
 
- Tighten the air intake duct/MAF sensor hose clamps.
 
- Connect the MAF sensor electrical connector.