Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Engine Cooling Schematics , HVAC Schematics , in HVAC Systems - Automatic or HVAC Schematics in HVAC Systems - Manual Connector End View Reference: Cooling System Connector End Views DEFINITION: One or both engine cooling fan motors run continuously in high or low speed.  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information  | 
2  | Turn ON the ignition, with the engine OFF. Are one or both cooling fans ON?  | Go to Step 3  | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems  | 
3  | Are both cooling fans running continuously?  | Go to Step 4  | Go to Step 6  | 
4  | Are both cooling fans running continuously in high speed?  | Go to Step 5  | Go to Step 7  | 
5  | Test the low reference circuit of the A/C refrigerant pressure sensor for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition?  | Go to Step 18  | Go to Step 14  | 
6  | Remove the cool fan 3 or S/P relay. Did the right cooling fan turn OFF?  | Go to Step 10  | Go to Step 8  | 
7  | Remove the cool fan 1 relay. Did the cooling fans turn OFF?  | Go to Step 12  | Go to Step 9  | 
8  | Remove the cool fan 2 relay. Did the right cooling fan turn OFF?  | Go to Step 13  | Go to Step 11  | 
9  | Repair the short to voltage in the left cooling fan motor supply voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | Go to Step 18  | --  | 
10  | Repair the short to voltage in the left cooling fan low reference circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | Go to Step 18  | --  | 
11  | Repair the short to voltage in the right cooling fan motor supply voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair?  | Go to Step 18  | --  | 
12  | Inspect for poor connections at the cool fan 1 relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Repairs. Did you find and correct the condition?  | Go to Step 18  | Go to Step 15  | 
13  | Inspect for poor connections at the cool fan 2 relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Repairs. Did you find and correct the condition?  | Go to Step 18  | Go to Step 16  | 
14  | Inspect for poor connections at the A/C refrigerant pressure sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Repairs. Did you find and correct the condition?  | Go to Step 18  | Go to Step 17  | 
15  | Replace the cool fan 1 relay. Did you complete the replacement?  | Go to Step 18  | --  | 
16  | Replace the cool fan 2 relay. Did you complete the replacement?  | Go to Step 18  | --  | 
17  | Replace the A/C refrigerant pressure sensor. Refer to Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement in Heating, Ventilation, and Air Conditioning. Did you complete the replacement?  | Go to Step 18  | --  | 
18  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 2  |