The number below refers to the step number on the diagnostic table.
Step  | Action  | Yes  | No  | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON.  | |||||||||||||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |||||||||||
2  | 
 Does the recirculation door move from the recirculation to the outside air position?  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | ||||||||||
3  | Except for the blower motor speed, are all of the functions of the HVAC control module inoperative?  | Go to Step 9  | Go to Step 4  | ||||||||||
4  | 
 Does the test lamp illuminate?  | Go to Step 5  | Go to Step 15  | ||||||||||
5  | Test the ground circuit of the recirculation actuator for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 18  | Go to Step 6  | ||||||||||
6  | 
 Does the recirculation door move into the outside air position?  | Go to Step 14  | Go to Step 7  | ||||||||||
7  | Test the door control circuit of the recirculation actuator for an open, for a high resistance, for a short to ground, or for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 18  | Go to Step 8  | ||||||||||
8  | Inspect the recirculation door and the recirculation actuator for the following conditions: 
 
 
 
 
 Did you find and correct the condition?  | Go to Step 18  | Go to Step 13  | ||||||||||
Test the ignition 3 voltage circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 18  | Go to Step 10  | |||||||||||
10  | Test the battery positive voltage circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 18  | Go to Step 11  | ||||||||||
11  | Test the ground circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 18  | Go to Step 12  | ||||||||||
12  | Test the off blower motor control circuit of the HVAC control module for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 18  | Go to Step 14  | ||||||||||
13  | Inspect for bad connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 18  | Go to Step 16  | ||||||||||
14  | Inspect for bad connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 18  | Go to Step 17  | ||||||||||
15  | Repair the ignition 3 voltage circuit of the recirculation actuator. Refer to Wiring Repairs . Did you complete the repair?  | Go to Step 18  | --  | ||||||||||
16  | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement?  | Go to Step 18  | --  | ||||||||||
17  | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | Go to Step 18  | --  | ||||||||||
18  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  | ||||||||||