The number below refers to the step number on the diagnostic table.
Step  | Action  | Values  | Yes  | No  | 
|---|---|---|---|---|
| 
 Caution: Do not connect a jumper cable directly to the negative terminal of a discharged battery to prevent sparking and possible explosion of battery gases.  | ||||
 Does the bulb pass the visual and physical inspections?  | --  | Go to Step 3  | Go to Step 2  | |
2  | Replace the bulb. Is the repair complete?  | --  | System OK  | --  | 
3  | 
 Is fuse EF22 open?  | --  | Go to Step 4  | Go to Step 5  | 
4  | 
 Is the repair complete?  | --  | System OK  | --  | 
5  | Test fuse EF22. Does the voltage at fuse EF22 equal the specified value?  | 11-14 V  | Go to Step 7  | Go to Step 6  | 
6  | Repair the open power supply circuit for fuse EF22. Is the repair complete?  | --  | System OK  | --  | 
7  | 
 Does the voltage at connector terminal 2 equal the value specified?  | 11-14 V  | Go to Step 8  | Go to Step 9  | 
8  | Repair the open circuit between fuse EF22 and the interior courtesy lamp terminal 2. Is the repair complete?  | --  | System OK  | --  | 
9  | 
 Does the ohmmeter indicate continuity?  | --  | Go to Step 10  | Go to Step 11  | 
10  | Replace the interior courtesy lamp switch assembly. Is the repair complete?  | --  | System OK  | --  | 
11  | Repair the ground circuit for the interior courtesy lamp. Is the repair complete?  | --  | System OK  | --  |