Removal Procedure
- Remove the positive crankcase ventilation (PCV) fresh air tube from the air cleaner intake duct.
 
- Disconnect the mass air flow (MAF)/intake air temperature (IAT) sensor electrical connector.
 
- Loosen the clamps and remove the air cleaner intake duct with the MAF/IAT sensor from the throttle body and
the air cleaner housing cover.
 
- Loosen the clamp and remove the MAF/IAT sensor from the air cleaner intake duct.
 
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Install the MAF/IAT sensor to the air cleaner intake duct.
 
Tighten
Tighten the clamp to 2 N·m (18 lb in).
- Install the air cleaner intake duct with the MAF/IAT sensor to the throttle body and the air cleaner housing cover.
 
Tighten
Tighten the clamps to 2 N·m (18 lb in).
- Connect the MAF/IAT sensor electrical connector.
 
- Install the PCV fresh air tube to the air cleaner intake duct.
 
- Start and idle the engine.
 
- Inspect the air intake duct for leaks.