Generator Bracket Replacement LZ4
                    
Removal Procedure
- Disconnect the negative battery cable. Refer to 
Battery Negative Cable Disconnection and Connection
 .
 
- Rotate the drive belt tensioner counterclockwise.
 
- Remove the accessory drive belt. Refer to 
Drive Belt Replacement
 .
 
- Remove the generator. Refer to 
Generator Replacement
 .
 
- Remove the drive belt tensioner bolt.
 
- Remove the drive belt tensioner. 
 
- Remove the drive belt idler pulley bolt.
 
- Remove the drive belt idler pulley.
 
- Remove the generator bracket bolts.
 
- Remove the generator bracket.
 
Installation Procedure
- Install the generator bracket.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the generator bracket bolts.
 
Tighten
Tighten the bolts in sequence to 50 N·m (37 lb ft).
- Install the drive belt tensioner.
 
- Install the drive belt tensioner bolt.
 
Tighten
Tighten the bolt to 50 N·m (37 lb ft).
- Install the drive belt idler pulley.
 
- Install the drive belt idler pulley bolt.
 
Tighten
Tighten the bolt to 50 N·m (37 lb ft).
- Install the generator. Refer to 
Generator Replacement
 .
 
- Rotate the drive belt tensioner counterclockwise.
 
- Install the accessory drive belt. Refer to 
Drive Belt Replacement
 .
 
- Connect the negative battery cable. Refer to 
Battery Negative Cable Disconnection and Connection
 .