| Table 1: | HVAC Control Module Scan Tool Data Parameters | 
| Table 2: | HVAC Control Module Scan Tool Output Controls | 
Parameter  | System State  | Expected Value  | Description  | 
|---|---|---|---|
Operating Conditions: Ignition ON, HVAC OFF  | |||
A/C Request  | --  | No  | The scan tool displays Yes or No. Yes is displayed if the air conditioner is requested.  | 
Ambient Air Temp. Sensor  | --  | Varies  | This displays °F (°C). This is the current temperature at the ambient air temperature sensor.  | 
Ambient Light Sensor  | --  | Varies  | This displays Counts. This is the current ambient light measured in counts at the ambient light sensor.  | 
Blower Motor Speed  | --  | 0%  | This displays %. This is the current blower motor speed measured in percentage.  | 
Blower Motor Speed Command  | --  | 0%  | This displays %. This is the commanded blower motor speed measured in percentage.  | 
Driver Program Number  | --  | Varies  | This displays Counts. This is the driver program number measured in counts.  | 
Driver Temp. Dr. Cal. Range  | --  | Varies  | This displays Pulses. This is the driver temperature door calibration range measured in pulses.  | 
Driver Temp. Dr. Motor Command  | --  | Varies  | This displays Counts. This is the commanded driver temperature door motor request measured in counts.  | 
Driver Temp. Dr. Position  | --  | Varies  | This displays Counts or Pulses. This is the current driver temperature door position measured in either counts or pulses.  | 
Inside Air Temp. Sensor  | --  | Varies  | This displays °F (°C). This is the current temperature at the inside air temperature sensor.  | 
LED Intensity  | --  | Varies  | This displays Counts. This is the light emitting diode (LED) intensity measured in counts.  | 
Left Sunload Sensor  | --  | Varies  | This displays Counts. This is the current sunload measured in counts at the driver sunload sensor.  | 
Load Management Status  | --  | Off  | The scan tool displays On or Off. This is the status of the load management.  | 
Lower Left Duct Temp. Sensor  | --  | Varies  | This displays Counts. This is the current temperature at the driver lower duct temperature sensor measured in counts.  | 
Lower Right Duct Temp. Sensor  | --  | Varies  | This displays Counts. This is the current temperature at the passenger lower duct temperature sensor measured in counts.  | 
Mode Door Position  | --  | Varies  | This displays Counts or Pulses. This is the current mode door position measured in either counts or pulses.  | 
Mode Dr. Cal. Range  | --  | Varies  | This displays Pulses. This is the mode door calibration range measured in pulses.  | 
Mode Dr. Motor Command  | --  | Varies  | This displays Counts. This is the commanded mode door motor request measured in counts.  | 
Mode Status  | --  | Off  | The scan tool displays Off, Auto, Heater, Bi-Level, Defog, Defrost or Mid. This is the current mode of the HVAC system.  | 
Psgr. Program Number  | --  | Varies  | This displays Counts. This is the passenger program number measured in counts.  | 
Psgr. Temp. Dr. Cal. Range  | --  | Varies  | This displays Pulses. This is the passenger temperature door calibration range measured in pulses.  | 
Psgr. Temp. Dr. Motor Command  | --  | Varies  | This displays Counts. This is the commanded passenger temperature door motor request measured in counts.  | 
Psgr. Temp. Dr. Position  | --  | Varies  | This displays Counts or Pulses. This is the current passenger temperature door position measured in either counts or pulses.  | 
Recirculation Temp. Dr. Cal. Range  | --  | Varies  | This displays Pulses. This is the recirculation temperature door calibration range measured in pulses.  | 
Recirculation Temp. Dr. Motor Command  | --  | Varies  | This displays Counts. This is the commanded recirculation temperature door motor request measured in counts.  | 
Recirculation Temp. Dr. Position  | --  | Varies  | This displays Counts or Pulses. This is the current recirculation temperature door position measured in either counts or pulses.  | 
Right Sunload Sensor  | --  | Varies  | This displays Counts. This is the current sunload measured in counts at the passenger sunload sensor.  | 
Seat Temp. Status  | --  | Off  | The scan tool displays Off, Max. Cool, Mid. Cool, Min. Cool, Max. Heat, Mid. Heat or Min. Heat. This is the current state of the driver seat temperature.  | 
Upper Left Duct Temp. Sensor  | --  | Varies  | This displays Counts. This is the current temperature at the driver upper duct temperature sensor measured in counts.  | 
Upper Right Duct Temp. Sensor  | --  | Varies  | This displays Counts. This is the current temperature at the passenger upper duct temperature sensor measured in counts.  | 
Valet Switch  | --  | Inactive  | The scan tool displays Active or Inactive. This is the state of the valet switch.  | 
Vehicle Speed  | --  | 0 km/h (0 mph)  | This displays km/h (mph). This is the current vehicle speed.  | 
Output Control  | Description  | 
|---|---|
Afterblow Option  | When afterblow is activated the scan tool displays an *.  | 
Blower Motor  | The scan tool displays Off or On selections. This function allows you to command the blower motor to its maximum (100%) or minimum (0%) speeds for 5 seconds.  | 
Compressor Clutch  | The scan tool displays the A/C compressor clutch status: Engage or Disengage. This function allows you to command the A/C compressor clutch On and Off.  | 
Driver Temp. Door  | The scan tool displays On or Off selections. The selection drives the actuator to its minimum (cold) or maximum (hot) positions for 20 seconds.  | 
Instant OAT Update  | The scan tool displays Commanded State: On or Off. This function updates the HVAC control module ambient air temperature input to the current raw value.  | 
Mode Door Position  | The scan tool displays On or Off selections. This function drives the actuator to its minimum (defrost) or maximum (upper) positions for 20 seconds.  | 
Passenger Temp. Door  | The scan tool displays On or Off selections. The selection drives the actuator to its minimum (hot) or maximum (cold) positions for 20 seconds.  | 
Recalibrate All Motors  | When commanded the scan tool displays the actuators counts moving from hot to cold until the re-cal is complete.  | 
Recirculation Door  | The scan tool displays On or Off selections. This function drives the actuator to its minimum (outside air) or maximum (recirculate) stops for 20 seconds.  |