Tools Required
J 39400-A 
 Halogen Leak Detector
Removal Procedure
Important: Refrigerant recovery is not required.
- Remove the refrigerant pressure sensor wire harness connector. 
 
- Remove the refrigerant pressure sensor.
 
- Remove and discard the O-ring.
 
Installation Procedure
- Install a new O-ring. Refer to 
O-Ring Replacement
 .
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the refrigerant pressure sensor.
 
Tighten
Tighten to 5 N·m (44 lb in).
- Install the refrigerant pressure sensor wire harness connector. 
 
- Leak test the fittings using the 
J 39400-A 
 .