Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets.  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |
2  | 
 Is the blower motor OFF?  | Go to Step 3  | Go to Blower Motor Always On  | 
3  | Place the blower motor switch in each speed position. Does the blower motor operate in each speed position?  | Go to Step 4  | Go to Blower Motor Inoperative  | 
4  | Does the blower motor operate at the desired speeds?  | Go to Step 5  | Go to Blower Motor Malfunction  | 
5  | 
 Does the scan tool display any DTCs?  | Go to Step 6  | |
6  | Place the mode switch in each mode position. Does the air flow from the correct air distribution outlets in each selected mode position?  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 7  | 
7  | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 10  | Go to Step 8  | 
8  | Inspect and the air distribution system for the following conditions: 
 Did you find and correct the condition?  | Go to Step 10  | Go to Step 9  | 
9  | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | Go to Step 10  | --  | 
10  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |