Removal Procedure
- Remove the right side instrument panel (I/P) insulator. Refer to 
Instrument Panel Insulator Panel Replacement - Right Side 
 in Instrument
Panel, Gages and Console.
 
- Remove the I/P compartment. Refer to 
Instrument Panel Compartment Replacement 
 in Instrument Panel, Gages and Console.
 
- Remove
the screws retaining the air temperature actuator (2).
 
- Disconnect the electrical connector from the air temperature actuator.
 
- Remove the air temperature actuator from the HVAC Module Assembly.
 
Installation Procedure
- Position
the air temperature actuator (2). Align the slots in the electric actuator driver
 to the flats on the shaft.
 
- Align the locating hole to the alignment pin on the HVAC module case.
 
- Slide the actuator driver on the shaft. The actuator driver should sit
completely on the shaft and the mounting holes should be flush with the HVAC module
case.
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws to the air temperature actuator.
 
Tighten
Tighten the screw to 1.5 N·m (13 lb in).
- Connect the electrical connector to the air temperature actuator.
 
- Install the I/P compartment. Refer to 
Instrument Panel Compartment Replacement 
 in Instrument Panel, Gages, and Console.
 
- Install the right side I/P insulator. Refer to 
Instrument Panel Insulator Panel Replacement - Right Side 
in Instrument Panel, Gages,
and Console.
 
- Calibrate the actuator. Refer to 
Actuator Recalibration 
.