Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Ignition ON/Engine OFF/Vehicle in PARK  | |||
Auto Learn Timer  | Security Data  | Seconds  | 0-600  | 
Battery 1  | Security Data  | Volts  | Varies  | 
Driver Door Switch  | Switch Inputs  | Active/Inactive  | Inactive (door closed)  | 
Horn Relay Command  | Security Data  | Active/Inactive  | Inactive  | 
Horn Relay Feedback  | Security Data  | Active/Inactive  | Inactive  | 
Ignition 1 Input  | Security Data  | Active/Inactive  | Active  | 
Ignition 2 Input  | Security Data  | Active/Inactive  | Active  | 
Key Learned  | Security Data  | Numerical  | Varies  | 
Key Learn Enable  | Security Data  | Active/Inactive  | Inactive  | 
Passanger Door Switches  | Switch Inputs  | Active/Inactive  | Inactive (Door Closed)  | 
Passlock Input  | Security Data  | Volts  | 0.86-5 Volts  | 
Passlock Power Feedback  | Security Data  | Ignition Off/Tamper/Fail Enable/Fail Enable Dec/Seedkey Lrn Pend/Seedkey Learn/Auto Learn Pend/Learn Passlock/Monitor Passlock/Normal Decision/Auto Learn  | Monitor Passlock  | 
Passlock Timer  | Security Data  | Seconds  | Varies  | 
Security LED  | Security Data  | On/Off/Flashing  | Off  | 
Scan Tool Parameter  | Data List  | Units Displayed  | Typical Data Value  | 
|---|---|---|---|
Ignition ON/Engine OFF/Vehicle in PARK  | |||
VTD Auto Learn Timer  | Engine Data 3  | Active/Inactive  | Inactive  | 
VTD Fuel Disable  | Engine Data 3  | Active/Inactive  | Inactive  | 
VTD Fuel Disable Until  | Engine Data 3  | Yes/No  | No  | 
VTD Password Learn Enable  | Engine Data 3  | Yes/No  | No  |