Removal Procedure
- Disconnect the vacuum switching valve connector (3).
 
- Disconnect the wire harness clamp.
 
- Disconnect the 2 purge line hoses (1, 2) from the vacuum switching valve.
 
- Remove the vacuum switching valve.
 
Installation Procedure
- Install the vacuum switching valve onto the air cleaner hose.
 
- Connect the 2 purge line hoses (1, 2) to the vacuum switching valve.
 
- Connect the wire harness clamp.
 
- Connect the vacuum switching valve connector (3).