Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Instrument Cluster Schematics Connector End View Reference: Component Connector End Views  | |||
1  | Did you review the Instrument Panel, Gages and Console Description and Operation and perform the necessary inspections?  | Go to Step 2  | |
2  | Verify that the instrument cluster gages are inoperative. Does the system operate normally?  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | 
3  | 
 Does an open condition exist?  | Go to Step 4  | Go to Step 5  | 
4  | Repair the open in the WH/BK wire between the instrument cluster and G200. Refer to Wiring Repairs . Did you complete the repair?  | Go to Step 8  | --  | 
5  | With connector still disconnected, test terminal 1 for open or short to ground. Refer to Circuit Testing . Is open or short present?  | Go to Step 6  | Go to Step 7  | 
6  | Repair the open or short to ground. Refer to Wiring Repairs . Did you repair short or open?  | Go to Step 8  | --  | 
7  | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Did you complete the replacement?  | Go to Step 8  | --  | 
8  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |