Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Instrument Cluster Schematics Connector End View Reference: Component Connector End Views  | |||
1  | Did you review the Power Door system Description and Operation?  | Go to Step 2  | |
2  | Disable the dome lamp override switch. Is the dome lamp or the door ajar indicator always on?  | Go to Dome Lamps Always On  | Go to Step 3  | 
3  | Open each door individually while observing the dome lamps. Does the dome lamp illuminate with each door?  | Go to Step 4  | Go to Dome Lamps Inoperative  | 
4  | 
 Does the test lamp illuminate?  | Go to Step 5  | Go to Step 6  | 
5  | Inspect for poor connections at the IPC connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 10  | Go to Step 9  | 
6  | Test for a short to ground in the door ajar indicator control circuit between the multifunction alarm module and the IPC. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 10  | Go to Step 7  | 
7  | Inspect for poor connections at the multifunction alarm module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 10  | Go to Step 8  | 
8  | Replace the body control module (BCM). Refer to Control Module References . Did you complete the replacement?  | Go to Step 10  | |
9  | Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement?  | Go to Step 10  | |
10  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 2  |