Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: Instrument Cluster Schematics Connector End View Reference: Component Connector End Views  | |||
1  | Did you review the Instrument Cluster Description and perform the necessary inspections?  | Go to Step 2  | |
2  | Verify the outside temperature display is inaccurate or inoperative. Does the system operate normally?  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | 
3  | Measure the resistance between cavity 1 and 2 of the ambient air temperature sensor. Refer to Ambient Air Temperature Sensor Resistance for proper resistance specifications. Is resistance within specs?  | Go to Step 4  | Go to Step 11  | 
4  | With the ignition in the ON position. Test cavity 1 of the ambient air temperature sensor harness connector for a 5-volt reference signal. Refer to Circuit Testing . Is the voltage present?  | Go to Step 5  | Go Step 6  | 
5  | Test cavity 2 of the ambient temperature sensor harness connector for continuity to ground. Refer to Circuit Testing . Is a ground present?  | Go to Step 10  | Go to Step 7  | 
6  | With the ignition in the ON position, test cavity 38 of the instrument panel cluster harness connector for a 5-volt reference signal. Refer to Circuit Testing . Is the voltage present?  | Go to Step 8  | Go to Step 10  | 
7  | Test cavity 39 of the Instrument panel cluster harness connector for continuity to ground. Is a ground present?  | Go to Step 9  | Go to Step 10  | 
8  | Repair the open or high resistance in 5-volt referance circuit between cavity 38 of the I/P cluster and caity 1 of the ambient air temperature sensor. Refer to Wiring Repairs . Did you complete the repair?  | Go to Step 12  | --  | 
9  | Repair the open or high resistance in the ambient temperature sensor ground circuit between cavity 39 of the I/P cluster and cavity 2 of the ambient temperature sensor Refer to Wiring Repairs . Did you complete the repair?  | Go to Step 12  | --  | 
10  | Replace the instrument panel cluster. Refer to Instrument Cluster Replacement . Did you complete the replacement?  | Go to Step 12  | --  | 
11  | Replace the ambient air temperature sensor. Did you complete the repair?  | Go to Step 12  | --  | 
12  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 3  |