The pressure sensor is installed on the high pressure line to detect refrigerant pressure, outputs a refrigerant pressure signal to the A/C amplifier. The A/C amplifier converts this signal to pressure according to the sensor characteristics to control the compressor. When refrigerant pressure on the high pressure side is extremely low 0.19 Mpa (2.0 kgf/cm², (28 psi)) or extremely high 3.14 Mpa (32.0 kgf/cm², (455 psi)) or more, this DTC will set.
This diagnostic procedure supports the following DTC:
DTC B1423 Pressure Sensor Circuit
This DTC shall run when the engine is running.
| • | When refrigerant pressure on the high pressure side is extremely low 0.19 MPa (2.0 kgf/cm², (28 psi)) or less, or extremely high 03.14 MPa (32.0 kgf/cm², (455 psi)) or more. | 
| • | Open or short in pressure sensor circuit. | 
The
The DTC will clear when conditions for setting the DTC have been repaired.
Step  | Action  | Value(s)  | Yes  | No  | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: Component Connector End Views  | ||||||||||||||||||
1  | Did you perform the Diagnostic System Check - Vehicle?  | --  | Go to Step 2  | |||||||||||||||
2  | 
 Is the voltage measured within the specified values?  | 4.75 -5.25 V  | Go to Step 3  | Go to Step 6  | ||||||||||||||
3  | 
 Is the resistance measured within the specified value?  | Below 1 Ohm  | Go to Step 4  | Go to Step 7  | ||||||||||||||
4  | 
 Is the voltage measured within the specified values?  | 0.7-4.8 V  | Go to Step 5  | Go to Step 8  | ||||||||||||||
5  | 
 
 
 
 
 
 
 
 Is the voltage measured within the specified values?  | 0.7-4.8 V  | Go to Step 22  | Go to Step 14  | ||||||||||||||
6  | 
 Are the voltages measured within the specified values?  | Between connector A16 terminal 3 and E62 terminal 1 = Below 1 Ohm Between connector E62 terminal 1 and body ground = 10 Kohm or higher  | Go to Step 22  | Go to Step 19  | ||||||||||||||
7  | 
 Are the voltages measured within the specified values?  | Between connector A16 terminal 1 and E62 terminal 4 = Below 1 Ohm Between connector E62 terminal 4 and body ground = 10 Kohm or higher  | Go to Step 22  | Go to Step 19  | ||||||||||||||
8  | 
 Are the voltages measured within the specified values?  | Between connector A16 terminal 2 and E62 terminal 6 = Below 1 Ohm Between connector E62 terminal 6 and body ground = 10 Kohm or higher  | Go to Step 9  | Go to Step 19  | ||||||||||||||
9  | 
 Was vacuum maintained?  | --  | Go to Step 10  | Go to Step 13  | ||||||||||||||
10  | 
 Did you complete the refrigerant charging?  | --  | Go to Step 11  | --  | ||||||||||||||
11  | 
 
 
 
 
 
 
 
 Does DTC reset?  | --  | Go to Step 12  | Go to Step 25  | ||||||||||||||
12  | 
 Is the voltage measured within the specified values?  | 1.0-4.8 V  | Go to Step 22  | Go to Step 20  | ||||||||||||||
13  | 
 Did you complete the repair?  | --  | Go to Step 15  | --  | ||||||||||||||
14  | Check that the cooling fan operates normally. Does the cooling fan operate normally?  | --  | Go to Step 17  | Go to Cooling Fan Inoperative  | ||||||||||||||
15  | 
 Did you complete the refrigerant charging?  | --  | Go to Step 16  | --  | ||||||||||||||
16  | 
 
 
 
 
 
 
 
 Does DTC reset?  | --  | Go to Step 21  | Go to Step 23  | ||||||||||||||
17  | 
 Did you complete the refrigerant charging?  | --  | Go to Step 18  | --  | ||||||||||||||
18  | 
 
 
 
 
 
 
 
 Does DTC reset?  | --  | Go to Step 24  | Go to Step 25  | ||||||||||||||
19  | Repair or replace harness or connector between the ambient temperature sensor and instrument panel. Did you complete the repair or replacement?  | --  | Go to Step 25  | --  | ||||||||||||||
20  | Replace the A/C pressure sensor. Did you complete the replacement?  | --  | Go to Step 25  | --  | ||||||||||||||
21  | Replace the expansion valve. Did you complete the replacement?  | --  | Go to Step 25  | --  | ||||||||||||||
22  | Replace the A/C amplifier. Did you complete the replacement?  | --  | Go to Step 25  | --  | ||||||||||||||
23  | Replace the cooler dryer. Did you complete the replacement?  | --  | Go to Step 25  | --  | ||||||||||||||
24  | Replace the condenser. Did you complete the replacement?  | --  | Go to Step 25  | --  | ||||||||||||||
25  | 
 Does the DTC reset?  | --  | Go to Step 2  | System OK  | ||||||||||||||